CVE-2024-5769

CVE-2024-5769

Título es
CVE-2024-5769

Jue, 09/01/2025 – 11:15

Tipo
CWE-862

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-5769

Descripción en
The MIMO Woocommerce Order Tracking plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on several functions in all versions up to, and including, 1.0.2. This makes it possible for authenticated attackers, with Subscriber-level access and above, to add, update, and delete shipper tracking settings.

09/01/2025
09/01/2025
Vector CVSS:3.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N

Gravedad 3.1 (CVSS 3.1 Base Score)
4.30

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
MEDIUM

Enviar en el boletín
Off

CVE-2024-43658

CVE-2024-43658

Título es
CVE-2024-43658

Jue, 09/01/2025 – 08:15

Tipo
CWE-27

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43658

Descripción en
Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files
This issue affects Iocharger firmware for AC model before firmware version 25010801.

Likelihood: High, but requires authentication

Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:X/V:X/RE:X/U:X

Gravedad 4.0
7.20

Gravedad 4.0 txt
HIGH

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2024-43657

CVE-2024-43657

Título es
CVE-2024-43657

Jue, 09/01/2025 – 08:15

Tipo
CWE-78

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43657

Descripción en
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root

This issue affects Iocharger firmware for AC model chargers before version 24120701.

Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.

Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:Y/R:X/V:X/RE:X/U:X

Gravedad 4.0
9.30

Gravedad 4.0 txt
CRITICAL

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2024-43663

CVE-2024-43663

Título es
CVE-2024-43663

Jue, 09/01/2025 – 08:15

Tipo
CWE-121

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43663

Descripción en
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.

Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.

Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.

CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect  this vulnerability to have a safety impact. The attack can be automated (AU:Y).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:X/RE:X/U:X

Gravedad 4.0
5.30

Gravedad 4.0 txt
MEDIUM

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2024-43662

CVE-2024-43662

Título es
CVE-2024-43662

Jue, 09/01/2025 – 08:15

Tipo
CWE-434

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43662

Descripción en
The .exe or .exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.

This issue affects Iocharger firmware for AC models before version 24120701.

Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the .exe or .exe CGI binary and upload the file, or convince a user with such access to upload it.

Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.

CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:X

Gravedad 4.0
5.30

Gravedad 4.0 txt
MEDIUM

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2024-43661

CVE-2024-43661

Título es
CVE-2024-43661

Jue, 09/01/2025 – 08:15

Tipo
CWE-121

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43661

Descripción en
The .so library, which is used by , is
vulnerable to a buffer overflow in the code that handles the deletion
of certificates. This buffer overflow can be triggered by providing a
long file path to the action of the .exe CGI binary or
to the .sh CGI script. This binary or script will write this
file path to , which is then
read by .so

This issue affects Iocharger firmware for AC models before version 24120701.

Likelihood: Moderate – An attacker will have to find this exploit by
either obtaining the binaries involved in this vulnerability, or by trial
and error. Furthermore, the attacker will need a (low privilege)
account to gain access to the .exe CGI binary or .sh
script to trigger the vulnerability, or convince a user with such access
send an HTTP request that triggers it.

Impact: High – The process, which we assume is
responsible for OCPP communication, will keep crashing after
performing the exploit. This happens because the buffer overflow
causes the process to segfault before
is removed. This means that,
even though is automatically restarted, it will crash
again as soon as it tries to parse the text file.

CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:I/V:X/RE:X/U:X

Gravedad 4.0
7.10

Gravedad 4.0 txt
HIGH

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2024-43660

CVE-2024-43660

Título es
CVE-2024-43660

Jue, 09/01/2025 – 08:15

Tipo
CWE-552

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43660

Descripción en
The CGI script .sh can be used to download any file on the filesystem.

This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.

Likelihood: High, but credentials required.

Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:X

Gravedad 4.0
7.10

Gravedad 4.0 txt
HIGH

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2024-43659

CVE-2024-43659

Título es
CVE-2024-43659

Jue, 09/01/2025 – 08:15

Tipo
CWE-256

Gravedad 2.0 Txt
Pendiente de análisis

Título en

CVE-2024-43659

Descripción en
After gaining access to the firmware of a charging station, a file at can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.

This issue affects Iocharger firmware for AC models before firmware version 25010801.

The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.

Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using .sh) to gain access to the .json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.

Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:X/RE:X/U:X

Gravedad 4.0
8.30

Gravedad 4.0 txt
HIGH

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
Pendiente de análisis

Enviar en el boletín
Off

CVE-2025-0344

CVE-2025-0344

Título es
CVE-2025-0344

Jue, 09/01/2025 – 08:15

Tipo
CWE-74

Gravedad v2.0
6.50

Gravedad 2.0 Txt
MEDIUM

Título en

CVE-2025-0344

Descripción en
A vulnerability has been found in leiyuxi cy-fast 1.0 and classified as critical. Affected by this vulnerability is the function listData of the file /commpara/listData. The manipulation of the argument order leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vector CVSS:3.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

Vector CVSS:2.0
AV:N/AC:L/Au:S/C:P/I:P/A:P

Gravedad 4.0
5.30

Gravedad 4.0 txt
MEDIUM

Gravedad 3.1 (CVSS 3.1 Base Score)
6.30

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
MEDIUM

Enviar en el boletín
Off

CVE-2025-0342

CVE-2025-0342

Título es
CVE-2025-0342

Jue, 09/01/2025 – 08:15

Tipo
CWE-79

Gravedad v2.0
4.00

Gravedad 2.0 Txt
MEDIUM

Título en

CVE-2025-0342

Descripción en
A vulnerability, which was classified as problematic, was found in CampCodes Computer Laboratory Management System 1.0. This affects an unknown part of the file /class/edit/edit. The manipulation of the argument s_lname leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

09/01/2025
09/01/2025
Vector CVSS:4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Vector CVSS:3.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N

Vector CVSS:2.0
AV:N/AC:L/Au:S/C:N/I:P/A:N

Gravedad 4.0
5.30

Gravedad 4.0 txt
MEDIUM

Gravedad 3.1 (CVSS 3.1 Base Score)
3.50

Gravedad 3.1 Txt Gravedad 3.1 (CVSS 3.1 Base Score)
LOW

Enviar en el boletín
Off